{"product_id":"trac-outdoor-bilge-pump-12v-auto-800-1100-gph-trc-69311","title":"Trac Outdoor Bilge Pump 12V Auto 800\/1100 Gph","description":"\u003ch2\u003eTRAC Automatic 800\/1100 GPH Bilge Pump\u003c\/h2\u003e \u003cp\u003eThe TRAC 69311 Automatic Bilge Pump is a versatile pump that includes both a 800 GPH 3\/4\" outlet and a 1100 GPH 1-1\/8\" outlet. This automatic, self-priming bilge pump from TRAC is ideal for all watercraft. It is ignition protected, has a low power draw, and can run dry without damage. Designed for easy installation and retrofitting, the bilge pump body accepts both 3\/4\" and 1-1\/8\" screw-on outlets. This automatic bilge pump has an integrated float switch that allows for automatic ON\/OFF functionality. \u003c\/p\u003e \u003cp\u003eUniversal strainer base is connection-compatible to fit Attwood Tsunami, Rule, Johnson\/Mayfair cartridge pumps. Screw mounting holes match Rule and Attwood Tsunami. The strainer base also includes a side mounting option for installation in tight spaces.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInternal Integrated Float Switch for auto ON\/OFF functionality\u003c\/li\u003e \u003cli\u003eCartridge style pump head\u003c\/li\u003e \u003cli\u003eEach outlet has an O-ring for easy maneuverability without stripping\u003c\/li\u003e \u003cli\u003eIgnition protected with low power draw\u003c\/li\u003e \u003cli\u003eRuns dry without damage\u003c\/li\u003e \u003cli\u003eMeets ABYC, NMMA, Coast Guard and ISO marine standards \u003c\/li\u003e \u003cli\u003e1 Year warranty\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e3\/4\" Dia. Outlet: 800 GPH\u003c\/li\u003e \u003cli\u003e1-1\/8\" Dia. Outlet: 1100 GPH\u003c\/li\u003e \u003cli\u003e5 AMP Fuse: 12v DC\u003c\/li\u003e \u003cli\u003e3.7A @ 13.6v DC\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eHow To Install TRAC Auto Bilge Pump\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eRemove strainer base from pump body by depressing the tabs on each side of pump and slide base off.\u003c\/li\u003e \u003cli\u003eInstall strainer base with stainless steel screws.\u003c\/li\u003e \u003cli\u003eInsert pump in strainer base making sure tabs lock in place.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eRotate the outlet fitting so it is pointing upward. Tighten outlet connector nut (hand tight).\u003c\/li\u003e \u003cli\u003eYou must route the hose continuously rising from the pump to the Thru-Hull fitting. The hose should run as short as possible.\u003c\/li\u003e \u003cli\u003eAttach all hoses with stainless steel hose clamps.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eUse 16 Gauge marine-grade tinned wire.\u003c\/li\u003e \u003cli\u003eConnect brown wires as noted below.\u003c\/li\u003e \u003cli\u003eBlack (-) wire is negative and connects to the negative terminal of the battery.\u003c\/li\u003e \u003cli\u003eInstall a 5 amp fuse in the brown wire as near as possible to the battery.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eTrac Automatic Bilge Pumps can be wired ozne of (3) three ways. A 3-position (AUTO\/OFF\/MANUAL) panel switch is recommended. You may also install with a 2-position (ON\/OFF) switch or no panel switch.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e3-Position Panel Switch\u003c\/strong\u003e(AUTO\/OFF\/MANUAL)\u003c\/p\u003e \u003cp\u003eThe ON position is a momentary ON, meaning the switch has to be held in the ON position to test the pump or make it run for a few seconds. As the switch is released, it springs back to the OFF position.\u003c\/p\u003e \u003cp\u003eThe AUTO position is where the pump normally operates. In this position, the pump’s internal float switch makes the pump turn ON and OFF as the water rises and falls.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWire Connections\u003c\/strong\u003e \u003cul\u003e \u003cli\u003eBlack wire to battery negative terminal.\u003c\/li\u003e \u003cli\u003eBrown wire with White Stripe to the switch ON terminal.\u003c\/li\u003e \u003cli\u003eBrown wire to the switch’s AUTO terminal.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e2-Position Panel Switch \u003c\/strong\u003e(ON\/OFF)\u003c\/p\u003e \u003cp\u003eWhen using the 2-position switch, the pump is in AUTO mode when the switch is ON. When ON, the pump has power, so if approximately 2” water enters the bilge, the pump will turn on automatically.\u003c\/p\u003e \u003cp\u003eWhen the switch is OFF, power is interrupted to the pump and it will not turn on when water is present.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWire Connections\u003c\/strong\u003e \u003cul\u003e \u003cli\u003eBlack wire to battery negative terminal.\u003c\/li\u003e \u003cli\u003eBrown wire with White Stripe is not used and should be routed with the other brown wire above high water level.\u003c\/li\u003e \u003cli\u003eBrown wire to the switch’s ON terminal.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eNo Panel Switch\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eWhen using no switch, the pump is in AUTO mode when wired to a power source. If approximately 2” water enters the bilge, the pump will turn on automatically and off when the pump begins to suck air.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eWire Connections\u003c\/strong\u003e \u003cul\u003e \u003cli\u003eBlack wire to battery negative terminal\u003c\/li\u003e \u003cli\u003eBrown wire with White Stripe is not used and should be routed with the other brown wire above high water level.\u003c\/li\u003e \u003cli\u003eBrown wire to the battery’s positive terminal. \u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInformation sourced from TRAC Automatic Bilge Pump Installation Instructions.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.wholesalemarine.com\/content\/PDFs\/TRAC-AUTO-Bilge-Pump-Manual.pdf\"\u003e\u003cimg class=\"__mce_add_custom__\" title=\"pdficon.png\" src=\"https:\/\/cdn11.bigcommerce.com\/s-6rtev5owwo\/product_images\/uploaded_images\/pdficon.png\" alt=\"pdficon.png\" width=\"58\" height=\"55\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.wholesalemarine.com\/content\/PDFs\/TRAC-AUTO-Bilge-Pump-Manual.pdf\"\u003eClick Here to Download Installation Instructions for Trac Auto 800\/1100 GPH Bilge Pump\u003c\/a\u003e \u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003c!-- snippet location product_description --\u003e \u003cp\u003e California Residents: \u003cimg src=\"https:\/\/cdn11.bigcommerce.com\/s-6rtev5owwo\/stencil\/4c731d90-821b-013f-159c-7692448c53ea\/e\/5184b8b0-7ec1-013f-1cb3-16eaae88d95a\/img\/warning.png\" alt=\"warning sign\" class=\"warningImg\"\u003e \u003cstrong\u003e WARNING \u003c\/strong\u003e Cancer and Reproductive Harm - \u003ca href=\"https:\/\/www.p65warnings.ca.gov\/\" class=\"productWarning\"\u003eP65Warnings.ca.gov\u003c\/a\u003e \u003c\/p\u003e","brand":"Trac Outdoor","offers":[{"title":"Default Title","offer_id":67606446440763,"sku":"TRC-69311","price":81.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/4271\/8779\/files\/trc-t10012_lg__85870.1558172211.jpg?v=1790721276","url":"https:\/\/clinchriverfishingusa.com\/products\/trac-outdoor-bilge-pump-12v-auto-800-1100-gph-trc-69311","provider":"Clinch River Fishing USA","version":"1.0","type":"link"}